{"created":"2021-03-01T06:31:41.656465+00:00","id":26142,"links":{},"metadata":{"_buckets":{"deposit":"ec942ce3-db58-48f1-b2db-31bce63281cf"},"_deposit":{"id":"26142","owners":[],"pid":{"revision_id":0,"type":"depid","value":"26142"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00026142","sets":["432:1291:1292:1345","453:456"]},"item_7_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Effect of Bonding Agents on Adaptation of Light Cured Composite Resin Restorations to Dentin Cavities : Part2, Adaptation after Storage in Water up to 4 Weeks"}]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"13","bibliographicPageStart":"9","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"新潟歯学会雑誌"},{"bibliographic_title":"新潟歯学会雑誌","bibliographic_titleLang":"en"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Adaptation of the light-cured composite resins with bonding agents to the cavity walls of human dentin were examined and shear bond strength of the same composite system to human dentin was evaluated after immersion of the specimens in water. Sylindrical dentin cavities, 3.0 mm in diameter, 1.3 mm in depth and 90°cavosurface angle, were prepared in extracted human molar teeth. Two types of bonding-system (Gluma/Lumifor and Scotchbond l.c. /P30) were used to restore the cavities. Specimens were stored in deionized water at room temperature for 1D, 1W, 2W and 4W, respectively. Maximum gaps along axial walls and cavity floors were measured microscopically. Shear bond specimens prepared by means of same bonding-system mentioned above were also stored in deionized water for 1D, 1W and 4W, then shear strength was evaluated. The following results were drawn from this study;\\n1.Gap width became narrower in accordance with the immersion periods of the specimens in water, this phenomina was much pronounced at side wall than at cavity floors.\\n2.Shear bond strength mediated with Gluma/Lumifor system exhibited a slight increased up to 4W. Gaps along axcial wall closed down almost completely after 2W immersion in water. \\n3.Scotchbond 1.c.,/P30 system showed a relatively low and constant shear bond strength throughout the observation period. Gap width gradually became narrower in accordance with the periods of water immersion.","subitem_description_type":"Abstract"}]},"item_7_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"154385","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ohsawa, Masahiro"}]}]},"item_7_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟歯学会"}]},"item_7_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_7_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN0018300X","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03850153","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大澤, 雅博"}],"nameIdentifiers":[{"nameIdentifier":"154383","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Finger, Werner"}],"nameIdentifiers":[{"nameIdentifier":"154384","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-19"}],"displaytype":"detail","filename":"NS_16(2)_9-13.pdf","filesize":[{"value":"394.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"NS_16(2)_9-13.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/26142/files/NS_16(2)_9-13.pdf"},"version_id":"ad2abf02-fe46-4abd-a269-c568c9800468"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"光重合型コンポジットレジン","subitem_subject_scheme":"Other"},{"subitem_subject":"ボンディング剤","subitem_subject_scheme":"Other"},{"subitem_subject":"窩洞適合性","subitem_subject_scheme":"Other"},{"subitem_subject":"剪断接着力","subitem_subject_scheme":"Other"},{"subitem_subject":"象牙質窩洞","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"象牙質窩洞において光重合型コンポジットレジンと組合わせたボンディング剤のGap阻止効果 : 第2報、1ヵ月後の状態","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"象牙質窩洞において光重合型コンポジットレジンと組合わせたボンディング剤のGap阻止効果 : 第2報、1ヵ月後の状態"},{"subitem_title":"象牙質窩洞において光重合型コンポジットレジンと組合わせたボンディング剤のGap阻止効果 : 第2報、1ヵ月後の状態","subitem_title_language":"en"}]},"item_type_id":"7","owner":"1","path":["456","1345"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-07-12"},"publish_date":"2012-07-12","publish_status":"0","recid":"26142","relation_version_is_last":true,"title":["象牙質窩洞において光重合型コンポジットレジンと組合わせたボンディング剤のGap阻止効果 : 第2報、1ヵ月後の状態"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:56:10.264545+00:00"}