{"created":"2021-03-01T06:31:27.876612+00:00","id":25937,"links":{},"metadata":{"_buckets":{"deposit":"b2c94624-2f02-4143-b53b-e84409c47c1e"},"_deposit":{"id":"25937","owners":[],"pid":{"revision_id":0,"type":"depid","value":"25937"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00025937","sets":["432:1291:1292:1326","453:456"]},"item_7_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Treatment of obstructive sleep apnea syndrome with oral appliance: report of 2 cases"}]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"73","bibliographicPageStart":"67","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"新潟歯学会雑誌"},{"bibliographic_title":"新潟歯学会雑誌","bibliographic_titleLang":"en"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Two cases of obstructive sleep apnea syndrome treated conservatively by a oral appliance are reported. Case 1 was a 60-year-old man with elongated soft palate and narrow posterior air way space. On polysomnography, apnea and hypopnea were observed 94 times and 13 times, respectively and ST depression was noted during apnea on ECG. The minimum SpO2 was 68% and SpO2 decreased below 90% 52 times and for 1470 seconds during sleep. Because of myocardial infarction, surgical treatment was abandoned and a oral appliance was set to put the mandible anteriorly by 7mm and posteriorly by 6mm. It resulted in an increase of the posterior air way space. The minimum SpO2 became 86%. The number and time of SpO2 below 90% also decreased to 23 times and 390 seconds, respectively. Respiration disturbance during sleep was markedly improved. No complications associated with the appliance were encountered. Case 2 was a 49-year-old man who had sleep apnea due to excessive elongation of the soft palate and narrowing of the posterior air way space. Apnea and hypopnea were encountered 75 times and 32 times during sleep, respectively. The minimum SpO2 Was 56% and SpO2 decreased below 90% 92 times and for 1985 seconds. All these values were aggravated just before hemodialysis due to thickning of the soft palate. The mandible was set anteiorly and posteriorly by 6mm. Then, there was a 1.9mm increase of the posterior air way space which was accompanied by an improvement of SpO2 and disappearance of nocturnal respiration difficulties. The dental appliance was found to be effective in the treatment of obstructive sleep apnea syndrome.","subitem_description_type":"Abstract"},{"subitem_description":"口腔内装置で保存的に治療した睡眠時無呼吸症候群の2例について報告した。第1症例は、60歳男性で軟口蓋が長く咽頭気道の狭窄が認められた。睡眠ポリグラフで無呼吸数および低換気数は、それぞれ94回と13回を観察し、無呼吸時、心電図でSTの低下が記録された。睡眠中の最低SpO2は68%で、SpO2が90%未満となった回数は52回、その時間は1470秒であった。心筋梗塞を合併しているため外科治療は断念し、下顎を前方へ7mm、下方へ6mm移動した位置で歯科補綴装置を装着した。これにより、咽頭気道径が拡大する結果となった。最低SpO2は86%になった。SpO2が90%未満となった回数と時間はそれぞれ23回、390秒となった。睡眠中の呼吸障害は明らかに改善した。装置装着による副作用は認められなかった。第2症例は、49歳男性で軟口蓋が長く咽頭気道の狭窄があるための睡眠時無呼吸であった。睡眠中の無呼吸数および低換気数は、それぞれ75回と32回を観察した。最低SpO2は56%でSpO2が90%未満となった回数は92回、その時間は1985秒であった。これらの値は透析直前には軟口蓋が厚くなるために悪化した。下顎位は前方、下方に6mmの位置で装置を装着した。これにより咽頭気道径が1.9mm増加し、SpO2の改善と夜間の呼吸障害が消失した。口腔内装置は、閉塞型睡眠時無呼吸症候群の治療に有効であると思われた。","subitem_description_type":"Abstract"}]},"item_7_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"153130","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yonezawa, Masahiro"}]},{"nameIdentifiers":[{"nameIdentifier":"153131","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kohno, Masaki"}]},{"nameIdentifiers":[{"nameIdentifier":"153132","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakatani, Ken"}]},{"nameIdentifiers":[{"nameIdentifier":"153133","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakajima, Tamio"}]},{"nameIdentifiers":[{"nameIdentifier":"153134","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kobayashi, Hiroshi"}]},{"nameIdentifiers":[{"nameIdentifier":"153135","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tsuchida, Yukihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"153136","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kohno, Shoji"}]}]},"item_7_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟歯学会"}]},"item_7_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_7_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN0018300X","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03850153","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"米沢, 雅裕"}],"nameIdentifiers":[{"nameIdentifier":"153123","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野, 正己"}],"nameIdentifiers":[{"nameIdentifier":"153124","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中谷, 現"}],"nameIdentifiers":[{"nameIdentifier":"153125","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中島, 民雄"}],"nameIdentifiers":[{"nameIdentifier":"153126","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林, 博"}],"nameIdentifiers":[{"nameIdentifier":"153127","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"土田, 幸弘"}],"nameIdentifiers":[{"nameIdentifier":"153128","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野, 正司"}],"nameIdentifiers":[{"nameIdentifier":"153129","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-19"}],"displaytype":"detail","filename":"NS_26(1)_67-73.pdf","filesize":[{"value":"4.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"NS_26(1)_67-73.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/25937/files/NS_26(1)_67-73.pdf"},"version_id":"5b9d752a-2486-4aa2-bd6e-a2e3cb866069"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"閉塞型睡眠時無呼吸症候群","subitem_subject_scheme":"Other"},{"subitem_subject":"歯科補綴装置","subitem_subject_scheme":"Other"},{"subitem_subject":"ポリソムノグラフィー","subitem_subject_scheme":"Other"},{"subitem_subject":"パルスオキシメーター","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"口腔内装置により治療した閉塞型睡眠時無呼吸症候群の2例","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"口腔内装置により治療した閉塞型睡眠時無呼吸症候群の2例"},{"subitem_title":"口腔内装置により治療した閉塞型睡眠時無呼吸症候群の2例","subitem_title_language":"en"}]},"item_type_id":"7","owner":"1","path":["456","1326"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-08-21"},"publish_date":"2013-08-21","publish_status":"0","recid":"25937","relation_version_is_last":true,"title":["口腔内装置により治療した閉塞型睡眠時無呼吸症候群の2例"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:56:02.276923+00:00"}