{"created":"2021-03-01T06:29:34.978413+00:00","id":24239,"links":{},"metadata":{"_buckets":{"deposit":"501128a5-1d78-4736-bc69-02fe5668f9a7"},"_deposit":{"id":"24239","owners":[],"pid":{"revision_id":0,"type":"depid","value":"24239"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00024239","sets":["453:456","471:537:538:1236"]},"item_7_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The present status of viral diseases transmitted by blood and/or blood products (Indications and Problems in Tranfusion of Blood Components as of 1986)"}]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"191","bibliographicPageStart":"184","bibliographicVolumeNumber":"101","bibliographic_titles":[{"bibliographic_title":"新潟医学会雑誌"},{"bibliographic_title":"新潟医学会雑誌","bibliographic_titleLang":"en"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Transmission of infectious diseases by the administration of blood, its components or derivatives has been known since the beginning of transfusion. Cases of such transmission have increased with the striking increase of the use of blood produscts in the past ten years. Specially, the use of albumin and fresh frozen plasma (FFp) increased fifty times during that period. The risk of transmissible disease is extraordinarily high for blood collected from paid denors by commercial blood banks. Recently, more than ninety percent of Japan's supply of blood products comes from abroad. We tested for the anti-AIDS virus antibody in blood products sold by ELISA, IFA and western blot, and detected 62% positive in anti-HBs immuno globu-lin (HBIG) on and after 1982. Most commercial globulin preparations are still made by ethanol fraction. Since ethanol concentration greater than 20% inactivate the AIDS virus in vitro, there is no need for alarm forrecipients of current globulin preparations. Globulin administration has never been identified as a risk factor for AIDS despite of the extensive use of globulin. However, we hope to eliminate anti-AIDS virus antibody positive blood from blood products and to make manufacturers of blood products aware of the need for careful donor selection.","subitem_description_type":"Abstract"}]},"item_7_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"145040","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yoshihara, Namiko"}]}]},"item_7_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟医学会"}]},"item_7_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_7_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00182415","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00290440","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉原, なみ子"}],"nameIdentifiers":[{"nameIdentifier":"145039","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-19"}],"displaytype":"detail","filename":"101(3)_184-191.pdf","filesize":[{"value":"776.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"101(3)_184-191.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/24239/files/101(3)_184-191.pdf"},"version_id":"ba172698-40dd-4fa8-b986-0b19867cbe89"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"blood products","subitem_subject_scheme":"Other"},{"subitem_subject":"blood transmitted virus","subitem_subject_scheme":"Other"},{"subitem_subject":"AIDS","subitem_subject_scheme":"Other"},{"subitem_subject":"ATL","subitem_subject_scheme":"Other"},{"subitem_subject":"輸血後肝炎","subitem_subject_scheme":"Other"},{"subitem_subject":"血液製剤","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"7) 血液製剤によるウイルス感染の現況(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"7) 血液製剤によるウイルス感染の現況(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)"},{"subitem_title":"7) 血液製剤によるウイルス感染の現況(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)","subitem_title_language":"en"}]},"item_type_id":"7","owner":"1","path":["456","1236"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-01-07"},"publish_date":"2016-01-07","publish_status":"0","recid":"24239","relation_version_is_last":true,"title":["7) 血液製剤によるウイルス感染の現況(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:54:18.973099+00:00"}