{"created":"2021-03-01T06:28:25.511800+00:00","id":23194,"links":{},"metadata":{"_buckets":{"deposit":"9df99f87-7f30-4e59-8a8d-376a2d22f153"},"_deposit":{"id":"23194","owners":[],"pid":{"revision_id":0,"type":"depid","value":"23194"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00023194","sets":["453:456","471:537:538:1214"]},"item_7_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Experimental Investigation of Bridge Tendon Grafting in the Digital Flexor Sheath"}]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"42","bibliographicPageStart":"28","bibliographicVolumeNumber":"103","bibliographic_titles":[{"bibliographic_title":"新潟医学会雑誌"},{"bibliographic_title":"新潟医学会雑誌","bibliographic_titleLang":"en"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Based on the recent knowledge that tendon repair heals well within the digital flexor sheath, the author supposed that short bridge tendon graft within the sheath should heal well and therefore be worthwhile to try instead of classical Bunnell's free tendon grafting. Following experimental study was done with Japanese monkeys to investigate the validity of this idea. 1. One cm long short bridge graft in FDP tendon within the flexor sheath healed well and clinical application of this technique was considered to be justified. Adhesion at the suture sites at both stumps of the grafted tendon was much slighter in specimens with complete closure of the sheath than in those with partial resection of the sheath, examined 4 weeks and 3 months after the grafting. 2. In specimens in which resected portion of flexor sheath was substituted with a free graft of extensor retinaculum, adhesion at both suture sites of the short tendon graft was as slight as in specimen with complete closure of the sheath by replacing the partially raised flap of the sheath. 3. The reasons why adhesion at both suture sites of short tendon graft was comparatively slight in specimens with complete closure either with temporarily raised sheath flap or with a graft of extensor retinaculum were considered as follows: it prevented invasion of newly proliferated connective tissue into the suture sites and also it facilitated diffusion of the synovial fluid into the suture sites. 4. The results described above led to the conclusion that the flexor sheath should better be closed after short bridge tendon graft, although its advantage was not proved in clinical cases with direct tendon repair within the flexor sheath. 5. In experimental specimens with 4 cm long tendon graft whose distal suture was within the flexor sheath and whose proximal suture was outside of and proximal to the flexor sheath, adhesion of the grafted tendon within the sheath was much lighter than outside of it, although adhesion at both suture site was essentially of the same grade. 6. Even in specimens with adhesion around the grafted tendon, which occasionally took place, little adhesion was seen around the proper FDP tendon being located distal and proximal to the tendon graft. Therefore, localized tenolysis might suffice to release the adhesion. 7. Early postoperative motion gave rise to no good result in this experimental study causing disruption of the suture site, probably because control of motion was very difficult as in clinical cases of children. 8. Small series of clinical cases with this technique gave overall good result as expected through this experimental study.","subitem_description_type":"Abstract"}]},"item_7_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"139923","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakaya, Aisaku"}]}]},"item_7_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"新潟医学会"}]},"item_7_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_7_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00182415","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00290440","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"中屋, 愛作"}],"nameIdentifiers":[{"nameIdentifier":"139922","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-19"}],"displaytype":"detail","filename":"103(1)_28-42.pdf","filesize":[{"value":"9.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"103(1)_28-42.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/23194/files/103(1)_28-42.pdf"},"version_id":"d2640b8b-6ee2-4a25-b842-d33f88dd94ef"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"digital flexor tendon graft","subitem_subject_scheme":"Other"},{"subitem_subject":"digital flexor sheath","subitem_subject_scheme":"Other"},{"subitem_subject":"指屈筋腱移植","subitem_subject_scheme":"Other"},{"subitem_subject":"指屈筋腱鞘","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"指屈筋腱鞘内におけるbridge tendon graftに関する実験的研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"指屈筋腱鞘内におけるbridge tendon graftに関する実験的研究"},{"subitem_title":"指屈筋腱鞘内におけるbridge tendon graftに関する実験的研究","subitem_title_language":"en"}]},"item_type_id":"7","owner":"1","path":["456","1214"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-04-08"},"publish_date":"2016-04-08","publish_status":"0","recid":"23194","relation_version_is_last":true,"title":["指屈筋腱鞘内におけるbridge tendon graftに関する実験的研究"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:53:27.866817+00:00"}