@article{oai:niigata-u.repo.nii.ac.jp:00021255, author = {塚田, 一博 and 長谷川, 滋 and 富山, 武美 and 白井, 良夫 and 土屋, 嘉昭 and 内田, 克之 and 伊賀, 芳朗 and 岡村, 直孝 and 黒崎, 功 and 加藤, 英雄 and 山洞, 典正 and 杉本, 不二夫 and 大谷, 哲也 and 坪野, 俊広 and 佐藤, 好信 and 小山, 俊太郎 and 大竹, 雅広 and 中平, 啓子 and 青野, 高志 and 飯合, 恒夫 and 吉田, 奎介 and 武藤, 輝一}, issue = {11}, journal = {新潟医学会雑誌, 新潟医学会雑誌}, month = {Nov}, note = {Orthotopic liver transplantation using bio-pump during anhepatic phase was performed eight times in small pigs before clinical application. Twenty-four pigs weighning 9 to 14kg were used. A new circuit was devised for V-V bypass in this series. Mean blood flow rate of this V-V bypass was 23ml/min/kg. Duration of mean anhepatic phase was 69 min. Two recipients were died of hyperthermia due to anesthesia. Two were lost because of hyper-potassemia after the reperfusion of the graft. There were no death during the V-V bypass. Four pigs were awaken after the operation. The longest living recipient without immunosuppression therapy died 91 days after reciving the new liver. It is suggested that V-V bypass using bio-pump with the new circuit is useful during anhepatic phase of the liver transplantation even in small patients.}, pages = {760--764}, title = {幼豚におけるbio-pumpを用いた同所性肝移植とその臨床応用における問題点 : 手術手技を中心に}, volume = {105}, year = {1991} }