{"created":"2023-07-26T01:13:41.021972+00:00","id":2001079,"links":{},"metadata":{"_buckets":{"deposit":"f19a2fdf-949a-4b75-b00a-6ef8311cb95b"},"_deposit":{"created_by":4,"id":"2001079","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2001079"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:02001079","sets":["453:455","471:561:562"]},"author_link":[],"item_6_date_granted_51":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2023-03-23"}]},"item_6_degree_grantor_49":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"新潟大学"},{"subitem_degreegrantor_language":"en","subitem_degreegrantor_name":"Niigata University"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"13101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_6_degree_name_48":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_6_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"BACKGROUND Inappropriate shocks delivered by subcutaneous implantable cardioverter-defibrillators (S-ICDs) are most frequently caused by cardiac oversensing. However, the predictors for oversensing of S-ICD remain unclear. OBJECTIVE We aimed to investigate the predictors for oversensing of S-ICD, especially clinical impact of an electrocardiographic (ECG) change. METHODS We retrospectively enrolled 99 consecutive patients who underwent S-ICD implantation between 2013 and 2021. Oversensing events were defined as inappropriate charge of the capacitors induced by cardiac or noncardiac signals other than tachycardia. RESULTS During a median follow-up period of 34 months (interquartile range 20-50 months), 11 of 99 patients (11%) experienced 34 oversensing events and 4 patients (4%) received inappropriate shocks during their events. Six patients exhibited ECG changes (bundle branch block, 3; ventricular pacing, 1; inverted T wave, 1; poor R-wave progression, 1) during the follow-up period. Oversensing events were observed in 4 of 6 patients with ECG change (67%), and 3 patients underwent S-ICD removal because of inevitable shock. Contrastingly, of the remaining patients without ECG change, all 7 patients who experienced oversensing events could continue using S-ICD with the reprogramming sensing vector and/or restriction of excessive exercise. Logistic regression analysis showed that lower voltage of Sokolow-Lyon ECG (V1S+V5R) was the predictor of oversensing in patients without ECG change. When the cutoff value was 2.1 mV, the sensitivity, specificity, positive predictive value, and negative predictive value were 85.7%, 62.7%, 15.7%, and 98.1%, respectively. CONCLUSION Unavoidable oversensing resulting in S-ICD removal is caused by ECG change. Oversensing in patients without ECG change can be managed.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_6_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Heart Rhythm. 2022, 19(10), 1704-1711.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_6_description_53":{"attribute_name":"学位記番号","attribute_value_mlt":[{"subitem_description":"新大院博(医)第1132号","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_6_dissertation_number_52":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第5141号"}]},"item_6_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1016/j.hrthm.2022.05.037","subitem_relation_type_select":"DOI"}}]},"item_6_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2022 Heart Rhythm Society. All rights reserved.","subitem_rights_language":"en"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hakamata, Takahiro","creatorNameLang":"en"},{"creatorName":"袴田, 崇裕","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-07-26"}],"displaytype":"detail","filename":"r4nmk1132.pdf","filesize":[{"value":"561KB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","objectType":"fulltext","url":"https://niigata-u.repo.nii.ac.jp/record/2001079/files/r4nmk1132.pdf"},"version_id":"a2f2e7e4-2ba4-47dd-bccc-a774502f3f62"},{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-07-26"}],"displaytype":"detail","filename":"r4nmk1132_a.pdf","filesize":[{"value":"528KB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"要旨","objectType":"abstract","url":"https://niigata-u.repo.nii.ac.jp/record/2001079/files/r4nmk1132_a.pdf"},"version_id":"8243b365-5992-40c6-b786-70509428c775"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Oversensing","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Subcutaneous implantable cardioverter-defibrillator (S-ICD)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Inappropriate shocks (IASs)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ECG change","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators","subitem_title_language":"en"},{"subitem_title":"皮下埋め込み型除細動器のオーバーセンシングにおける心電図変化の臨床的影響","subitem_title_language":"ja"}]},"item_type_id":"6","owner":"4","path":["455","562"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-07-26"},"publish_date":"2023-07-26","publish_status":"0","recid":"2001079","relation_version_is_last":true,"title":["Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-07-26T01:13:51.097940+00:00"}