{"created":"2021-03-01T06:05:38.458594+00:00","id":1955,"links":{},"metadata":{"_buckets":{"deposit":"5ff72e35-fbb7-4059-935d-a108ae777b9d"},"_deposit":{"id":"1955","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1955"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001955","sets":["423:424:425","453:454"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1993-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageEnd":"1418","bibliographicPageStart":"1411","bibliographicVolumeNumber":"E76-D","bibliographic_titles":[{"bibliographic_title":"IEICE transactions on information and systems"},{"bibliographic_title":"IEICE transactions on information and systems","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We use the B spline function and apply the Oslo algorithm to minimize the number of control points in electrocardiogram (ECG) waveform compression under the limitation of evaluation indexes. This method is based on dynamic programming matching to transfer the control points of a reference ECG waveform to the succeeding ECG waveforms. This reduces the execution time for beat-to-beat processing. We also reduced the processing time at several compression stages. When the difference percent normalized root mean square difference is around 10, our method gives the highest compression ratio at a sampling frequency of 250 Hz.","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"電子情報通信学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ieice.org/jpn/trans_online/","subitem_relation_type_select":"URI"}},{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110003219554","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"copyright@1993 IEICE"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10826272","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09168532","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Saitoh, Yoshiaki"}],"nameIdentifiers":[{"nameIdentifier":"6375","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hasegawa, Yasushi"}],"nameIdentifiers":[{"nameIdentifier":"6376","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kiryu, Tohru"}],"nameIdentifiers":[{"nameIdentifier":"6377","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hori, Jun'ichi"}],"nameIdentifiers":[{"nameIdentifier":"6378","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"110003219554.pdf","filesize":[{"value":"839.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110003219554.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1955/files/110003219554.pdf"},"version_id":"22170eb5-bfb5-4471-b15d-ddfaaf96757d"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching (Special Section on ECG Data Compression)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching (Special Section on ECG Data Compression)"},{"subitem_title":"Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching (Special Section on ECG Data Compression)","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-24"},"publish_date":"2012-10-24","publish_status":"0","recid":"1955","relation_version_is_last":true,"title":["Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching (Special Section on ECG Data Compression)"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:34:48.398284+00:00"}