{"created":"2021-03-01T06:05:38.331464+00:00","id":1953,"links":{},"metadata":{"_buckets":{"deposit":"ba7edf72-b698-4c11-85d3-e1091213010d"},"_deposit":{"id":"1953","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1953"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001953"},"item_5_biblio_info_6":{"attribute_name":"\u66f8\u8a8c\u60c5\u5831","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"1416","bibliographicPageStart":"1409","bibliographicVolumeNumber":"E82-D","bibliographic_titles":[{"bibliographic_title":"IEICE transactions on information and systems"},{"bibliographic_title":"IEICE transactions on information and systems","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"\u6284\u9332","attribute_value_mlt":[{"subitem_description":"In the present paper we shall examine the real-time restoration of biomedical signals under additive noises. Biomedical signals measured by instruments such as catheter manometers, ambulatory electrocardiographs and thermo-dilution sensors are susceptible to distortion and noise. Therefore, such signals must be restored to their original states. In the present study, nonstationary biomedical signals are observed and described using a mathematical model, and several restoration filters that are composed of a series of applications of this model are proposed. These filters restored band-limited approximations of the original signals in real-time. In addition, redundancy is introduced into these restoration filters in order to suppress additive noise. Finally, an optimum filter that accounts for restoration error and additive noise is proposed.","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"\u51fa\u7248\u8005","attribute_value_mlt":[{"subitem_publisher":"\u96fb\u5b50\u60c5\u5831\u901a\u4fe1\u5b66\u4f1a"}]},"item_5_relation_31":{"attribute_name":"\u7570\u7248\u3067\u3042\u308b","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ieice.org/jpn/trans_online/index.html","subitem_relation_type_select":"URI"}},{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110003210079","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"\u6a29\u5229","attribute_value_mlt":[{"subitem_rights":"copyright@1999 IEICE"},{"subitem_rights":"\u672c\u6587\u30c7\u30fc\u30bf\u306f\u5b66\u5354\u4f1a\u306e\u8a31\u8afe\u306b\u57fa\u3065\u304dCiNii\u304b\u3089\u8907\u88fd\u3057\u305f\u3082\u306e\u3067\u3042\u308b"}]},"item_5_select_19":{"attribute_name":"\u8457\u8005\u7248\u30d5\u30e9\u30b0","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID","attribute_value_mlt":[{"subitem_source_identifier":"AA10826272","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09168532","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"\u8457\u8005","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hori, Junichi"}],"nameIdentifiers":[{"nameIdentifier":"6369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saitoh, Yoshiaki"}],"nameIdentifiers":[{"nameIdentifier":"6370","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kiryu, Tohru"}],"nameIdentifiers":[{"nameIdentifier":"6371","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"\u30d5\u30a1\u30a4\u30eb\u60c5\u5831","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"110003210079.pdf","filesize":[{"value":"838.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110003210079.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1953/files/110003210079.pdf"},"version_id":"893cda40-2a46-4d08-8e6e-0128f4e2e9d1"}]},"item_keyword":{"attribute_name":"\u30ad\u30fc\u30ef\u30fc\u30c9","attribute_value_mlt":[{"subitem_subject":"restoration","subitem_subject_scheme":"Other"},{"subitem_subject":"band-limitation","subitem_subject_scheme":"Other"},{"subitem_subject":"real-time","subitem_subject_scheme":"Other"},{"subitem_subject":"additive noise","subitem_subject_scheme":"Other"},{"subitem_subject":"redundancy","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"\u8a00\u8a9e","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"\u8cc7\u6e90\u30bf\u30a4\u30d7","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Real-Time Restoration of Nonstationatry Biomedical Signals under Additive Noises","item_titles":{"attribute_name":"\u30bf\u30a4\u30c8\u30eb","attribute_value_mlt":[{"subitem_title":"Real-Time Restoration of Nonstationatry Biomedical Signals under Additive Noises"},{"subitem_title":"Real-Time Restoration of Nonstationatry Biomedical Signals under Additive Noises","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["453/454","468/469/470"],"pubdate":{"attribute_name":"\u516c\u958b\u65e5","attribute_value":"2012-10-24"},"publish_date":"2012-10-24","publish_status":"0","recid":"1953","relation_version_is_last":true,"title":["Real-Time Restoration of Nonstationatry Biomedical Signals under Additive Noises"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2021-03-01T20:49:29.743917+00:00"}