{"created":"2021-03-01T06:05:30.750002+00:00","id":1831,"links":{},"metadata":{"_buckets":{"deposit":"0ee27edd-121c-4052-a4b9-4770a8244a3c"},"_deposit":{"id":"1831","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1831"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001831","sets":["453:454","468:469:470"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"8","bibliographicPageEnd":"1134","bibliographicPageStart":"1129","bibliographicVolumeNumber":"E79-B","bibliographic_titles":[{"bibliographic_title":"IEICE transactions on communications"},{"bibliographic_title":"IEICE transactions on communications","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Adapting the principle of parametron oscillation, a small implantable temperature sensor requiring no internal power supply is described. Since this sensor's oscillation frequency is half that of the excitation frequency, the oscillated signal can be measured from the reception side, free of any signal, interference, simply by positioning the sensor and the excitation antenna so that; 1) they are separated up to 95cm in the air; 2) a 41cm gap, the phantom equivalent of the thickness of the human abdomen maintain between them. In the temperature-dependent quartz resonator sensor, oscillation occurs only when frequency and temperature correspond. The excitation power is then adjusted so that the frequency bandwidth narrows. As a result, the margin of error in measuring the temperature is minimized;(±0.07℃).","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"電子情報通信学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ieice.org/jpn/trans_online/index.html","subitem_relation_type_select":"URI"}},{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110003217676","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"copyright@1996 IEICE"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10826261","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09168516","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Saitoh, Yoshiaki"}],"nameIdentifiers":[{"nameIdentifier":"5784","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanke, Akira"}],"nameIdentifiers":[{"nameIdentifier":"5785","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinozaki, Isamu"}],"nameIdentifiers":[{"nameIdentifier":"5786","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kiryu, Tohru"}],"nameIdentifiers":[{"nameIdentifier":"5787","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hori, Jun'ichi"}],"nameIdentifiers":[{"nameIdentifier":"5788","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"110003217676.pdf","filesize":[{"value":"586.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110003217676.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1831/files/110003217676.pdf"},"version_id":"9d876233-d4d0-40a9-bf7b-2e6acd55a83d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"parametron phenomenon","subitem_subject_scheme":"Other"},{"subitem_subject":"temperature sensor","subitem_subject_scheme":"Other"},{"subitem_subject":"quartz resonator","subitem_subject_scheme":"Other"},{"subitem_subject":"oscillation-center frequency","subitem_subject_scheme":"Other"},{"subitem_subject":"excitation power","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Implantable Temperature Measurement System Using the Parametron Phenomenon","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Implantable Temperature Measurement System Using the Parametron Phenomenon"},{"subitem_title":"Implantable Temperature Measurement System Using the Parametron Phenomenon","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","470"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-24"},"publish_date":"2012-10-24","publish_status":"0","recid":"1831","relation_version_is_last":true,"title":["Implantable Temperature Measurement System Using the Parametron Phenomenon"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:34:41.336320+00:00"}