{"created":"2021-03-01T06:05:23.679078+00:00","id":1719,"links":{},"metadata":{"_buckets":{"deposit":"da1e62c0-5fe6-4785-ba51-cbe817b156c4"},"_deposit":{"id":"1719","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1719"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001719","sets":["423:424:425","453:454"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1988-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"136","bibliographicPageStart":"130","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Electromagnetic Compatibility"},{"bibliographic_title":"IEEE Transactions on Electromagnetic Compatibility","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Radio propagation characteristics in an underground street crowded with pedestrians are presented. Measurements were carried out on vertical and horizontal polarization characteristics in a frequency range from 250 MHz to 12.4 GHz. In the analysis, the region with pedestrians is modeled as a lossy, homogeneous dielectric slab. Based on the method of effective dielectric constant, some numerical results are presented for the attenuation constant and for the field distribution in the cross section and are compared with experimental data. It is shown that the method is applicable in determining the propagation characteristics in underground streets crowded with pedestrians","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"19","nameIdentifierScheme":"WEKO"}],"names":[{"name":"山口, 芳雄"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1109/15.2398","subitem_relation_type_select":"DOI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©(1988) IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained the IEEE."}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA0066781X","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00189375","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamaguchi, Y."}],"nameIdentifiers":[{"nameIdentifier":"19","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Abe, T."}],"nameIdentifiers":[{"nameIdentifier":"5206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sekiguchi, T."}],"nameIdentifiers":[{"nameIdentifier":"5207","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"6_0004.pdf","filesize":[{"value":"839.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"6_0004.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1719/files/6_0004.pdf"},"version_id":"c25cce09-55db-4001-aa3d-9c23d9211535"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Propagation","subitem_subject_scheme":"Other"},{"subitem_subject":"UHF","subitem_subject_scheme":"Other"},{"subitem_subject":"microwave","subitem_subject_scheme":"Other"},{"subitem_subject":"underground street","subitem_subject_scheme":"Other"},{"subitem_subject":"pedestrians","subitem_subject_scheme":"Other"},{"subitem_subject":"attenuation constant","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Radio propagation characteristics in underground streets crowded with pedestrians","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Radio propagation characteristics in underground streets crowded with pedestrians"},{"subitem_title":"Radio propagation characteristics in underground streets crowded with pedestrians","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-04-08"},"publish_date":"2008-04-08","publish_status":"0","recid":"1719","relation_version_is_last":true,"title":["Radio propagation characteristics in underground streets crowded with pedestrians"],"weko_creator_id":"1","weko_shared_id":2},"updated":"2022-12-15T03:34:25.134156+00:00"}