{"created":"2021-03-01T06:05:23.190364+00:00","id":1711,"links":{},"metadata":{"_buckets":{"deposit":"3e315525-b9ab-4280-899b-4a159baf02b7"},"_deposit":{"id":"1711","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1711"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001711","sets":["423:424:425","453:454"]},"author_link":["5153","5154","5155","5156"],"control_number":"1711","item_1627363077551":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"1851","bibliographicPageStart":"1848","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents experimental and numerical simulation results of a 2-section coil subjected to overcurrent pulses in the temperature range 20-60 K. The experiment simulates a high-temperature superconducting (HTS) magnet for electric devices such as fault-current limiters, transformers, motors, and power lines under fault-mode overcurrent pulses. Each section of the test coil is layer-wound with Bi-2223/Ag composite tape, 3.5-mm wide and 0.23-mm thick, with the outer section wound directly over the inner section. A pulse current exceeds the critical current of each conductor and may drive each section normal. A constant current that follows the pulse current leaves each section in three possible conditions: completely superconducting, recovering, and quenching. Simulation agrees reasonably well with experiment.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/77.920208","subitem_relation_type_select":"DOI"}}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10791666","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sugawara, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"5153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Isogami, Hisashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"5154","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kowallis, Karl W.","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"5155","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwasa, Yukikazu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"5156","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"AscSUGA.pdf","filesize":[{"value":"217.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AscSUGA.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1711/files/AscSUGA.pdf"},"version_id":"194600f4-b239-4636-823d-1107c66b5aa0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"overcurrent pulse","subitem_subject_scheme":"Other"},{"subitem_subject":"HTS magnet","subitem_subject_scheme":"Other"},{"subitem_subject":"Bi-2223/Ag tap","subitem_subject_scheme":"Other"},{"subitem_subject":"quench/recovery","subitem_subject_scheme":"Other"},{"subitem_subject":"critical current","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Transient electrical and thermal responses of a 2-section BSCCO-2223 coil under overcurrent pulses","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Transient electrical and thermal responses of a 2-section BSCCO-2223 coil under overcurrent pulses","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-04-18"},"publish_date":"2013-04-18","publish_status":"0","recid":"1711","relation_version_is_last":true,"title":["Transient electrical and thermal responses of a 2-section BSCCO-2223 coil under overcurrent pulses"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-15T03:34:29.910244+00:00"}