{"created":"2021-03-01T06:05:12.651054+00:00","id":1540,"links":{},"metadata":{"_buckets":{"deposit":"780e65a0-5823-46cd-923b-1cdc85633971"},"_deposit":{"id":"1540","owners":[],"pid":{"revision_id":0,"type":"depid","value":"1540"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00001540","sets":["423:424:425","453:454"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"612","bibliographicPageStart":"606","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"Applied Optics"},{"bibliographic_title":"Applied Optics","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A novelty imaging system using photorefractive crystal BaTiO_3 and a controlled shutter sequence, which can be applied to the slow-motion detection of the object, is proposed. In this system the observation time scale is set to the desired long value uninfluenced by the time constant of the crystal that is used. This system utilizes a photorefractive beam-fanning effect in the BaTiO_3 crystal, so it is constructed simply by using only the object beam without suffering from the external disturbance that is intrinsic when the reference beam is used. Moreover, the visibility for an opaque object is also maintained by the use of an additional random-phase plate. We examine the basic characteristics and determine the appropriate conditions of the system.","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Optical Society of America"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.1364/AO.31.000606","subitem_relation_type_select":"DOI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 1992 Optical Society of America"},{"subitem_rights":"This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/AO.31.000606. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law."}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00543409","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00036935","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Suzuki, Takamasa"}],"nameIdentifiers":[{"nameIdentifier":"39","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sato, Takuso"}],"nameIdentifiers":[{"nameIdentifier":"4206","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"31_5_606-612.pdf","filesize":[{"value":"656.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"31_5_606-612.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/1540/files/31_5_606-612.pdf"},"version_id":"e4343878-f927-4620-b077-ab90d45f588b"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Novelty imaging system with a desired long-time scale using BaTiO3 and a controlled shutter sequence","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Novelty imaging system with a desired long-time scale using BaTiO3 and a controlled shutter sequence"},{"subitem_title":"Novelty imaging system with a desired long-time scale using BaTiO3 and a controlled shutter sequence","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-06-20"},"publish_date":"2014-06-20","publish_status":"0","recid":"1540","relation_version_is_last":true,"title":["Novelty imaging system with a desired long-time scale using BaTiO3 and a controlled shutter sequence"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:34:11.121636+00:00"}