2024-03-28T22:23:30Z
https://niigata-u.repo.nii.ac.jp/oai
oai:niigata-u.repo.nii.ac.jp:00003978
2022-12-15T03:36:59Z
453:454
468:469:470
STUDY ON OF THE EVALUATION METHOD OF A CROSS VENTILATED BUILDING PERFORMANCE
通風性能の定量的評価手法に関する研究
通風性能の定量的評価手法に関する研究
赤林, 伸一
46512
佐々木, 淑貴
46513
坂口, 淳
46514
富永, 禎秀
46515
Cross ventilation evaluation index
Local index
Site index
Building performance index
通風性能評価
地域指標
立地指標
建物性能指標
In this study, we evaluate cross ventilation by the multi zone network airflow simulation and the CFD. Cross-ventilated detached house is evaluated. Quantitative evaluation of the effect of cross ventilation is carried out. The analytic object is a standard residence model. The k-e turbulence model simulates the flow. The purpose of this simulation is to calculate indoor airflow velocity distribution. The muti-zone airflow network model analysis using TRNSYS-COMIS simulates the indoor temperature. Two different analyses are coupled, so that the long-term simulation is realized. This paper proposes to report on the outline of the evaluation index of natural cross ventilation performance. This paper has the point to (1) locality, (2) location, (3) building performance as factors which influenced indoor wind velocity, and show the outline of the evaluation method for natural cross ventilation performance.
journal article
日本建築学会
2003-06
application/pdf
日本建築学会環境系論文集
568
49
56
日本建築学会環境系論文集
AA11830377
13480685
https://niigata-u.repo.nii.ac.jp/record/3978/files/ZF_568_49-56.pdf
jpn
社団法人日本建築学会