WEKO3
アイテム
{"_buckets": {"deposit": "e069bbe3-8c68-4184-80bf-0e38a111ef05"}, "_deposit": {"id": "31098", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31098"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00031098", "sets": ["457", "521"]}, "item_8_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "915", "bibliographicPageStart": "910", "bibliographicVolumeNumber": "2007", "bibliographic_titles": [{"bibliographic_title": "The 7th International Conference on Power Electronics and Drive Systems(PEDS2007)"}, {"bibliographic_title": "The 7th International Conference on Power Electronics and Drive Systems(PEDS2007)", "bibliographic_titleLang": "en"}]}]}, "item_8_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An electric brake by a three-phase short-circuit system used as the brake equipment of a small wind turbine damages the rotor blades by a rapid revolution stopping of the generator. Moreover, the generators windings may also be damaged by a large short-circuit current. In this paper, the electric braking circuit using the NTC thermistors (negative temperature coefficient resistors) is proposed as a braking system for a cheaper and safe stop of the small wind turbine. The effect under the natural wind condition is examined by the field test using a 500W small wind turbine.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_8_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsui, Yuto"}], "nameIdentifiers": [{"nameIdentifier": "169654", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sugawara, Akira"}], "nameIdentifiers": [{"nameIdentifier": "169655", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Shingo"}], "nameIdentifiers": [{"nameIdentifier": "169656", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeda, Tomoaki"}], "nameIdentifiers": [{"nameIdentifier": "169657", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ito, Tsuguru"}], "nameIdentifiers": [{"nameIdentifier": "169658", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogura, Kazuo"}], "nameIdentifiers": [{"nameIdentifier": "169659", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "2007_910-915.pdf", "filesize": [{"value": "336.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 336500.0, "url": {"label": "2007_910-915.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/31098/files/2007_910-915.pdf"}, "version_id": "d104b999-57f4-4190-862c-1ff552aab23e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "wind power", "subitem_subject_scheme": "Other"}, {"subitem_subject": "small wind turbine", "subitem_subject_scheme": "Other"}, {"subitem_subject": "NTC thermistors", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition"}, {"subitem_title": "Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition", "subitem_title_language": "en"}]}, "item_type_id": "8", "owner": "1", "path": ["457", "521"], "permalink_uri": "http://hdl.handle.net/10191/21882", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-04-18"}, "publish_date": "2013-04-18", "publish_status": "0", "recid": "31098", "relation": {}, "relation_version_is_last": true, "title": ["Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition"], "weko_shared_id": null}
Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition
http://hdl.handle.net/10191/21882
http://hdl.handle.net/10191/218823713d5cd-cb62-4548-a040-b2acc00ce8d7
名前 / ファイル | ライセンス | アクション |
---|---|---|
2007_910-915.pdf (336.5 kB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-04-18 | |||||
タイトル | ||||||
タイトル | Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Braking Circuit of Small Wind Turbine Using NTC Thermistor under Natural Wind Condition | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | wind power | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | small wind turbine | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | NTC thermistors | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_5794 | |||||
タイプ | conference paper | |||||
著者 |
Matsui, Yuto
× Matsui, Yuto× Sugawara, Akira× Sato, Shingo× Takeda, Tomoaki× Ito, Tsuguru× Ogura, Kazuo |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An electric brake by a three-phase short-circuit system used as the brake equipment of a small wind turbine damages the rotor blades by a rapid revolution stopping of the generator. Moreover, the generators windings may also be damaged by a large short-circuit current. In this paper, the electric braking circuit using the NTC thermistors (negative temperature coefficient resistors) is proposed as a braking system for a cheaper and safe stop of the small wind turbine. The effect under the natural wind condition is examined by the field test using a 500W small wind turbine. | |||||
書誌情報 |
The 7th International Conference on Power Electronics and Drive Systems(PEDS2007) en : The 7th International Conference on Power Electronics and Drive Systems(PEDS2007) 巻 2007, p. 910-915, 発行日 2007-11 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
著者版フラグ | ||||||
値 | author |