WEKO3
アイテム
{"_buckets": {"deposit": "8c5b89a8-91ab-4059-96fe-652434b0b4b8"}, "_deposit": {"id": "2734", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2734"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002734", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A Method to Extract Various Vascular Features from Liver Images of CTAP"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "219", "bibliographicPageStart": "210", "bibliographicVolumeNumber": "22", "bibliographic_titles": [{"bibliographic_title": "医用画像情報学会雑誌"}, {"bibliographic_title": "医用画像情報学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Liver cirrhosis is usually diagnosed with histological findings of liver biopsy sample. However, liver biopsy, sampling liver tissues from a living donor, is an invasive technique, in which a direct puncture of the liver is needed. On the other hand, higher resolution of recent computed tomography(CT) has a potential to replace histology with objective and digital images, which are available without any invasive techniques. Here we present a system extracting various features of three-dimensional vasculature in the liver from images of CT aiming an objective and noninvasive diagnosis of liver cirrhosis.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38708", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ishikawa, Masahiro"}]}, {"nameIdentifiers": [{"nameIdentifier": "38709", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Uchida, Hidaka"}]}, {"nameIdentifiers": [{"nameIdentifier": "38710", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamaki, Toru"}]}, {"nameIdentifiers": [{"nameIdentifier": "38711", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yamamoto, Masanobu"}]}, {"nameIdentifiers": [{"nameIdentifier": "38712", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Igarashi, Masato"}]}, {"nameIdentifiers": [{"nameIdentifier": "38713", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Suda, Takeshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "38714", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Aoyagi, Yutaka"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "医用画像情報学会"}]}, "item_5_relation_31": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.mii-sci.jp/", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (C) 2005 医用画像情報学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきWebから複製したものである"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10156808", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09101543", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石川, 雅浩"}], "nameIdentifiers": [{"nameIdentifier": "38701", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内田, 日高"}], "nameIdentifiers": [{"nameIdentifier": "38702", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "玉木, 徹"}], "nameIdentifiers": [{"nameIdentifier": "38703", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 正信"}], "nameIdentifiers": [{"nameIdentifier": "38704", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "五十嵐, 正人"}], "nameIdentifiers": [{"nameIdentifier": "38705", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田, 剛士"}], "nameIdentifiers": [{"nameIdentifier": "38706", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青柳, 豊"}], "nameIdentifiers": [{"nameIdentifier": "38707", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "22_3_210-219.pdf", "filesize": [{"value": "520.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 520299.99999999994, "url": {"label": "22_3_210-219.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2734/files/22_3_210-219.pdf"}, "version_id": "025250f2-3e10-4fcb-8fb3-5656ef473512"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Computer aided diagnosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Liver cirrhosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computed Tomography", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "CTAPからの形状特徴量抽出のための一手法", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "CTAPからの形状特徴量抽出のための一手法"}, {"subitem_title": "CTAPからの形状特徴量抽出のための一手法", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/25761", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-02-25"}, "publish_date": "2014-02-25", "publish_status": "0", "recid": "2734", "relation": {}, "relation_version_is_last": true, "title": ["CTAPからの形状特徴量抽出のための一手法"], "weko_shared_id": null}
CTAPからの形状特徴量抽出のための一手法
http://hdl.handle.net/10191/25761
http://hdl.handle.net/10191/25761ba96f0af-baa0-4751-a7b8-576fdd9c4901
名前 / ファイル | ライセンス | アクション |
---|---|---|
22_3_210-219.pdf (520.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-25 | |||||
タイトル | ||||||
タイトル | CTAPからの形状特徴量抽出のための一手法 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | CTAPからの形状特徴量抽出のための一手法 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computer aided diagnosis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Liver cirrhosis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computed Tomography | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | A Method to Extract Various Vascular Features from Liver Images of CTAP | |||||
著者 |
石川, 雅浩
× 石川, 雅浩× 内田, 日高× 玉木, 徹× 山本, 正信× 五十嵐, 正人× 須田, 剛士× 青柳, 豊 |
|||||
著者別名 | ||||||
識別子 | 38708 | |||||
識別子Scheme | WEKO | |||||
姓名 | Ishikawa, Masahiro | |||||
著者別名 | ||||||
識別子 | 38709 | |||||
識別子Scheme | WEKO | |||||
姓名 | Uchida, Hidaka | |||||
著者別名 | ||||||
識別子 | 38710 | |||||
識別子Scheme | WEKO | |||||
姓名 | Tamaki, Toru | |||||
著者別名 | ||||||
識別子 | 38711 | |||||
識別子Scheme | WEKO | |||||
姓名 | Yamamoto, Masanobu | |||||
著者別名 | ||||||
識別子 | 38712 | |||||
識別子Scheme | WEKO | |||||
姓名 | Igarashi, Masato | |||||
著者別名 | ||||||
識別子 | 38713 | |||||
識別子Scheme | WEKO | |||||
姓名 | Suda, Takeshi | |||||
著者別名 | ||||||
識別子 | 38714 | |||||
識別子Scheme | WEKO | |||||
姓名 | Aoyagi, Yutaka | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Liver cirrhosis is usually diagnosed with histological findings of liver biopsy sample. However, liver biopsy, sampling liver tissues from a living donor, is an invasive technique, in which a direct puncture of the liver is needed. On the other hand, higher resolution of recent computed tomography(CT) has a potential to replace histology with objective and digital images, which are available without any invasive techniques. Here we present a system extracting various features of three-dimensional vasculature in the liver from images of CT aiming an objective and noninvasive diagnosis of liver cirrhosis. | |||||
書誌情報 |
医用画像情報学会雑誌 en : 医用画像情報学会雑誌 巻 22, 号 3, p. 210-219, 発行日 2005-03 |
|||||
出版者 | ||||||
出版者 | 医用画像情報学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09101543 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10156808 | |||||
権利 | ||||||
権利情報 | Copyright (C) 2005 医用画像情報学会 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきWebから複製したものである | |||||
著者版フラグ | ||||||
値 | publisher | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://www.mii-sci.jp/ |