WEKO3
アイテム
{"_buckets": {"deposit": "054316c2-7eda-4dc3-8c20-aa337a408e17"}, "_deposit": {"id": "25952", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "25952"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00025952", "sets": ["456", "1327"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Ceramic inlay restoration using a dental CAD/CAM system"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "86", "bibliographicPageStart": "79", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "新潟歯学会雑誌"}, {"bibliographic_title": "新潟歯学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The clinical technique of ceramic inlay restorations using a dental CAD/CAM CEREC system was introduced, and the clinical advantage and disadvantage of this system was discussed. Moreover, the adaptability of the CEREC inlays to the prepared cavities was compared with that of conventional laboratory fabricated porcelain inlays. Class Ⅱ MO cavities were prepared in extracted human premolars, and the ceramic inlays were made by the CEREC system or indirect laboratory-fired method. Each inlay was bonded by a resinous adhesive cement, then the restored teeth were sectioned mesiodistally, and adaptation to the cavity was determined by measuring the thickness of the adhesive cement. The cement thickness was 146~263㎛ for the CAD/CAM group and 72~170㎛ for the laboratory-fired group. Statistical analysis showed a significant difference between the CAD/CAM and laboratory-fired groups. The large cement line on the occlusal surface has been reported to result in selective wear of the exposed luting cements ; therefore, the use of wear-resistant luting materials is required.", "subitem_description_type": "Abstract"}, {"subitem_description": "歯科用CAD/CAM セレックシステムを用いたセラミックインレー修復の臨床術式を紹介し、本システムの長所と問題点について考察するとともに、本システムを用いて製作されたインレ-修復物の窩壁適合性を、従来の焼成法によるポーセレンインレーと比較評価した。ヒト抜去小臼歯に2級MOインレー窩洞を形成し、CAD/CAM システムあるいは焼成法により製作されたインレ-修復歯を近遠心方向に半切し、切断面上における修復物と歯質の間のセメント厚さを計測することにより適合性を評価した。その結果、CAD/CAM システムによるインレーのセメント厚さは146~263㎛であり、焼成法の72~170㎛に比較して有意に大きいことが判明した。大きな幅のセメントラインは咬合面においては選択的に摩耗を生じるという報告もあり、耐磨耗性に優れた接着材の応用が必要であると思われた。", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "153224", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ishikawa, Kazuyuki"}]}, {"nameIdentifiers": [{"nameIdentifier": "153225", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Fukushima, Masayoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "153226", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Iwaku, Masaaki"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟歯学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN0018300X", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03850153", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石川, 和之"}], "nameIdentifiers": [{"nameIdentifier": "153221", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福島, 正義"}], "nameIdentifiers": [{"nameIdentifier": "153222", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩久, 正明"}], "nameIdentifiers": [{"nameIdentifier": "153223", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "NS_25(2)_79-86.pdf", "filesize": [{"value": "5.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 5000000.0, "url": {"label": "NS_25(2)_79-86.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/25952/files/NS_25(2)_79-86.pdf"}, "version_id": "b413c6f6-5b4c-4b50-a50e-c0fcc8a266de"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "CAD/CAM", "subitem_subject_scheme": "Other"}, {"subitem_subject": "コンピューター支援設計/製作", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ceramic inlay", "subitem_subject_scheme": "Other"}, {"subitem_subject": "セラミックインレー", "subitem_subject_scheme": "Other"}, {"subitem_subject": "clinical technique", "subitem_subject_scheme": "Other"}, {"subitem_subject": "臨床技法", "subitem_subject_scheme": "Other"}, {"subitem_subject": "adaptability", "subitem_subject_scheme": "Other"}, {"subitem_subject": "適合性", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "歯科用CAD/CAMシステムを用いたセラミックインレー修復", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "歯科用CAD/CAMシステムを用いたセラミックインレー修復"}, {"subitem_title": "歯科用CAD/CAMシステムを用いたセラミックインレー修復", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "1327"], "permalink_uri": "http://hdl.handle.net/10191/22953", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-08-21"}, "publish_date": "2013-08-21", "publish_status": "0", "recid": "25952", "relation": {}, "relation_version_is_last": true, "title": ["歯科用CAD/CAMシステムを用いたセラミックインレー修復"], "weko_shared_id": null}
歯科用CAD/CAMシステムを用いたセラミックインレー修復
http://hdl.handle.net/10191/22953
http://hdl.handle.net/10191/22953e0ea3c8f-6aa4-49c9-9634-a2b1f7bd9cb7
名前 / ファイル | ライセンス | アクション |
---|---|---|
NS_25(2)_79-86.pdf (5.0 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-08-21 | |||||
タイトル | ||||||
タイトル | 歯科用CAD/CAMシステムを用いたセラミックインレー修復 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 歯科用CAD/CAMシステムを用いたセラミックインレー修復 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | CAD/CAM | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | コンピューター支援設計/製作 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ceramic inlay | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | セラミックインレー | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | clinical technique | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 臨床技法 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | adaptability | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 適合性 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Ceramic inlay restoration using a dental CAD/CAM system | |||||
著者 |
石川, 和之
× 石川, 和之× 福島, 正義× 岩久, 正明 |
|||||
著者別名 | ||||||
識別子 | 153224 | |||||
識別子Scheme | WEKO | |||||
姓名 | Ishikawa, Kazuyuki | |||||
著者別名 | ||||||
識別子 | 153225 | |||||
識別子Scheme | WEKO | |||||
姓名 | Fukushima, Masayoshi | |||||
著者別名 | ||||||
識別子 | 153226 | |||||
識別子Scheme | WEKO | |||||
姓名 | Iwaku, Masaaki | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The clinical technique of ceramic inlay restorations using a dental CAD/CAM CEREC system was introduced, and the clinical advantage and disadvantage of this system was discussed. Moreover, the adaptability of the CEREC inlays to the prepared cavities was compared with that of conventional laboratory fabricated porcelain inlays. Class Ⅱ MO cavities were prepared in extracted human premolars, and the ceramic inlays were made by the CEREC system or indirect laboratory-fired method. Each inlay was bonded by a resinous adhesive cement, then the restored teeth were sectioned mesiodistally, and adaptation to the cavity was determined by measuring the thickness of the adhesive cement. The cement thickness was 146~263㎛ for the CAD/CAM group and 72~170㎛ for the laboratory-fired group. Statistical analysis showed a significant difference between the CAD/CAM and laboratory-fired groups. The large cement line on the occlusal surface has been reported to result in selective wear of the exposed luting cements ; therefore, the use of wear-resistant luting materials is required. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 歯科用CAD/CAM セレックシステムを用いたセラミックインレー修復の臨床術式を紹介し、本システムの長所と問題点について考察するとともに、本システムを用いて製作されたインレ-修復物の窩壁適合性を、従来の焼成法によるポーセレンインレーと比較評価した。ヒト抜去小臼歯に2級MOインレー窩洞を形成し、CAD/CAM システムあるいは焼成法により製作されたインレ-修復歯を近遠心方向に半切し、切断面上における修復物と歯質の間のセメント厚さを計測することにより適合性を評価した。その結果、CAD/CAM システムによるインレーのセメント厚さは146~263㎛であり、焼成法の72~170㎛に比較して有意に大きいことが判明した。大きな幅のセメントラインは咬合面においては選択的に摩耗を生じるという報告もあり、耐磨耗性に優れた接着材の応用が必要であると思われた。 | |||||
書誌情報 |
新潟歯学会雑誌 en : 新潟歯学会雑誌 巻 25, 号 2, p. 79-86, 発行日 1995-12 |
|||||
出版者 | ||||||
出版者 | 新潟歯学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03850153 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN0018300X | |||||
著者版フラグ | ||||||
値 | publisher |