WEKO3
アイテム
{"_buckets": {"deposit": "b8879e07-3032-4df4-96f4-09f94ca6ec41"}, "_deposit": {"id": "21094", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "21094"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00021094", "sets": ["456", "1176"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Assessment of Body Composition using Bioelectrical Impedance Analysis in Healthy Volunteer and Patients undergoing Renal Dialysis"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1992-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "204", "bibliographicPageStart": "196", "bibliographicVolumeNumber": "106", "bibliographic_titles": [{"bibliographic_title": "新潟医学会雑誌"}, {"bibliographic_title": "新潟医学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The aim of this study was to determine accuracy of indices of body composition by bioelectrical impedance analysis (BIA). Measurements were performed in 60 normal Japanese volunteers (41 male, 19 female) and in 11 patients with chronic renal failure (7 male, 4 female), aged 25~85 yrs, Resistance was obtained by BIA using a tetrapolar electrode of 500μA and 50kHz current. Weight (Wt), height (Ht), arm circumference and triceps skinfold thickness (TSF) were measured in healthy subjects and twice measured in patients once before and once after dialysis. Lean body mass (LBM) and percentage fat (%BF) were expressed as Ht^2/R and RWt/Ht^2, respectively. Percent ideal body weight (%IBW), body mass index (BMI), body surface area (BSA), weight (BW)^\u003c0.75\u003e, arm muscle circumference (AMC) and arm muscle area (AMA) were calculated from the criterion methods. In healthy subjects, significant correlations were obtained between Ht^2/R and BSA, BW^\u003c0.75\u003e, AMC and AMA, respectively (p\u003c0.01, p\u003c0.01, p\u003c0.01, p\u003c0.01). Significant correlations were found between RW/Ht^2 and %IBW (p\u003c0.05), BMI(p\u003c0.01), and TSF (p\u003c0.01), respectively. There were significant differences in R, Ht^2/R and RW/Ht^2 before and after dialysis (p\u003c0.01, p\u003c0.01, p\u003c0.01). Significant positive correlations were seen between changes in Ht^2/R and both decreases in water (ml) and changes in weight following hemodialysis (p\u003c0.01, p\u003c0.01). The results suggest that the BIA is as reliable a method in determining LBM as anthropometric methods in a healthy Japanese population. The results also suggest that R is sensitive in detecting alternation in TBW. Changes in Ht^2/R are also useful in estimating changes in TBW associated with dialysis.", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "129370", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kusama, Akio"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00182415", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00290440", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "草間, 昭夫"}], "nameIdentifiers": [{"nameIdentifier": "129369", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "106(03)_196-204.pdf", "filesize": [{"value": "1.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1800000.0, "url": {"label": "106(03)_196-204.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/21094/files/106(03)_196-204.pdf"}, "version_id": "675ecebb-88dd-4ceb-bae2-e134c4daf2cb"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "BIA", "subitem_subject_scheme": "Other"}, {"subitem_subject": "body composition", "subitem_subject_scheme": "Other"}, {"subitem_subject": "hemodialysis", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討"}, {"subitem_title": "Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "1176"], "permalink_uri": "http://hdl.handle.net/10191/39571", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-03-14"}, "publish_date": "2016-03-14", "publish_status": "0", "recid": "21094", "relation": {}, "relation_version_is_last": true, "title": ["Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討"], "weko_shared_id": null}
Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討
http://hdl.handle.net/10191/39571
http://hdl.handle.net/10191/39571a6e45a16-f66a-4f33-8cfc-55a9893353e8
名前 / ファイル | ライセンス | アクション |
---|---|---|
106(03)_196-204.pdf (1.8 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-03-14 | |||||
タイトル | ||||||
タイトル | Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Bioelectrical Impedance Analysisによる身体組成評価 : 健常人及び血液透析患者による検討 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | BIA | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | body composition | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | hemodialysis | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Assessment of Body Composition using Bioelectrical Impedance Analysis in Healthy Volunteer and Patients undergoing Renal Dialysis | |||||
著者 |
草間, 昭夫
× 草間, 昭夫 |
|||||
著者別名 | ||||||
識別子 | 129370 | |||||
識別子Scheme | WEKO | |||||
姓名 | Kusama, Akio | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The aim of this study was to determine accuracy of indices of body composition by bioelectrical impedance analysis (BIA). Measurements were performed in 60 normal Japanese volunteers (41 male, 19 female) and in 11 patients with chronic renal failure (7 male, 4 female), aged 25~85 yrs, Resistance was obtained by BIA using a tetrapolar electrode of 500μA and 50kHz current. Weight (Wt), height (Ht), arm circumference and triceps skinfold thickness (TSF) were measured in healthy subjects and twice measured in patients once before and once after dialysis. Lean body mass (LBM) and percentage fat (%BF) were expressed as Ht^2/R and RWt/Ht^2, respectively. Percent ideal body weight (%IBW), body mass index (BMI), body surface area (BSA), weight (BW)^<0.75>, arm muscle circumference (AMC) and arm muscle area (AMA) were calculated from the criterion methods. In healthy subjects, significant correlations were obtained between Ht^2/R and BSA, BW^<0.75>, AMC and AMA, respectively (p<0.01, p<0.01, p<0.01, p<0.01). Significant correlations were found between RW/Ht^2 and %IBW (p<0.05), BMI(p<0.01), and TSF (p<0.01), respectively. There were significant differences in R, Ht^2/R and RW/Ht^2 before and after dialysis (p<0.01, p<0.01, p<0.01). Significant positive correlations were seen between changes in Ht^2/R and both decreases in water (ml) and changes in weight following hemodialysis (p<0.01, p<0.01). The results suggest that the BIA is as reliable a method in determining LBM as anthropometric methods in a healthy Japanese population. The results also suggest that R is sensitive in detecting alternation in TBW. Changes in Ht^2/R are also useful in estimating changes in TBW associated with dialysis. | |||||
書誌情報 |
新潟医学会雑誌 en : 新潟医学会雑誌 巻 106, 号 3, p. 196-204, 発行日 1992-03 |
|||||
出版者 | ||||||
出版者 | 新潟医学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00290440 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00182415 | |||||
著者版フラグ | ||||||
値 | publisher |